Search the collection
It's the ECG's that george rejects that makes George's ECG's the best.
Shifting Rabbit Ears in VT
Report: Ventricular tachycardia 152/min Possible old anterior infarction Comment: There is a monophasic R, possibly a qR, in V1, with northwest axis in the standard leads and QSs in V5-6. The patient in fact had an old anterior MI (Fig 106a below, in AF
Cardioverter-Defibrillator During Ventricular Tachycardia
Report:Ventricular tachycardia 133/min Burst of overdrive pacing 160/min Fusion beat Comment:This is the same patient as Case 4, five years later. The ICD does not always work, but the patient is alive, with numerous episodes of VT perhaps rendered les
Implanted Cardioverter-Defibrillator
Report:Implanted cardioverter-defibrillator (ICD) readout 1 Ventricular tachycardia 152 – 162/min 4 Burst overdrive pacing 190-245/min 4 Sinus rhythm 95/min 1 Comment:The patient had numerous runs of VT which failed to activate the ICD because the ra